Skip to content

03 · Test & Measurement

LIN RGB Test & Calibration

Volt, intensity and colour bins, checked against a golden reference.

Compares every RGB module side by side with a pre-calibrated golden module under the same LIN command, voltage and temperature, and calibrates over LIN where needed.

LINSpectrometer / colour sensorProgrammable PSUTraceability
LIN RGB test station with golden reference and DUT chambers, colour sensors and a CIE chromaticity display
3

bins per LED — volt

R·G·B·W

plus key colours checked on CIE x

9–16 V

supply sweep (example

The result is a difference, not an absolute

Measuring colour absolutely needs lab-grade instruments that drift on a production line. Here the result is the difference from a known-good module under the same conditions, so sensor ageing, fixture drift and ambient light cancel out.

Calibrate or reject

Within tolerance → PASS. Out of tolerance but correctable → calibrate over LIN, then re-verify. Out and not correctable → REJECT. Every value is logged against the module serial.

Interactive

Colour bins on the CIE diagram

0.10.10.20.20.30.30.40.40.50.50.60.60.70.7BIN C3○ golden ref ● DUT
Δx vs ref
—
Δy vs ref
—
Vf (R/G/B)
—
Iv @100 %
—
—

How it works

  1. 01

    Golden reference

    A pre-calibrated

  2. 02

    Same stimulus

    Both receive the same LIN command, supply voltage and temperature.

  3. 03

    Measure & compare

    Current, Vf, intensity and colour of every LED are compared with the reference.

  4. 04

    Calibrate over LIN

    If out but correctable

  5. 05

    Result + log

    PASS / CAL / REJECT, with all values stored.

Specifications

Volt bin
Forward voltage Vf of R
Intensity bin
If → Iv; brightness linearity at 10 / 50 / 100 % PWM
Colour bin
CIE 1931 x
Temperature
25 °C · 85 °C (to customer specification)
Bus
LIN 2.x master with LDF-based configuration

Final configuration is designed to your parts, cycle time and specifications.

← Previous
Vibration Micro-Drop Test
Next →
EOL Burn & Function Test

Start a project

Let's scope your LIN RGB Test & Calibration.

Send us a sample, a drawing or just a description. An engineer, not a salesperson, will reply within one working day.