Skip to content

01 · Programming

E522.88 OTP Programmers

Gang programming for volume, single-channel for flexibility.

An 8-channel gang workstation and a compact single-channel programmer for Elmos E522.88 LED drivers, with file revision and checksum control on every cycle.

USB-CSPII²CQR / barcodeLocal DB
Fuelbox E522.88 single-channel OTP programmer with terminal blocks and USB-C
8

independent channels programmed in parallel

≤ 4 s

program + verify per 8-IC panel (target)

8 wks

delivery from PO and complete inputs

Built around your panel

One breakable panel carries four PCBs and eight E522.88 ICs. The gang workstation gives every IC its own programming channel, so all eight are programmed and verified in parallel, and a failure on one is reported on its own without stopping the rest.

The fixture is designed from your panel CAD: bottom pogo pins, locating pins and a manual toggle clamp. The operator scans the panel QR code, closes the clamp and presses START. The status tower and the GUI show the result for each channel.

Traceable by default

Every cycle records the firmware file, its revision and checksum, the channel, the operator and the time. Records stay in the local database and can be sent to Production Traceability.

Interactive

Eight channels, eight independent results

Panel LMX-P-000418
CH1IDLE
PCB 1 · IC 1
CH2IDLE
PCB 1 · IC 2
CH3IDLE
PCB 2 · IC 1
CH4IDLE
PCB 2 · IC 2
CH5IDLE
PCB 3 · IC 1
CH6IDLE
PCB 3 · IC 2
CH7IDLE
PCB 4 · IC 1
CH8IDLE
PCB 4 · IC 2
Cycle time —
Result —
Image M110_HL_v1.2.5 · CRC 0x7A3F

Configurations

Gang programmer workstation

For volume production of breakable panels.

  • 8 channels, one per E522.88 on the panel (4 PCBs × 2 ICs)
  • Panel fixture with bottom pogo pins, toggle clamp and locating pins
  • Fixed QR scanner, START button and status tower
  • PC, monitor and trolley supplied as a complete station

Single-channel programmer

Compact bench unit for engineering and backup.

  • Rework, engineering samples, low volume and line backup
  • Same file control and logs as the gang station
  • START / RESET inputs for integration into other test stations
  • USB-C, status LEDs, pluggable terminal blocks

Gallery

8-channel gang workstation (concept)
8-channel gang workstation (concept)
Single-channel programmer
Single-channel programmer
Perspective view
Perspective view
Target and input terminals
Target and input terminals
USB-C to the PC
USB-C to the PC

Specifications

Target device
Elmos E522.88 (OTP)
Channels
8 (gang) · 1 (single)
Architecture
ESP32-S3 per channel
Target signals
GND, RST, PRG, SDA, SCL, VIN
Inputs
IN-1 START, IN-2 RESET
PC link
USB-C; Windows GUI with recipes and local database
Indicators
FILE / ERROR, TARGET / RUN; status tower on gang station

Final configuration is designed to your parts, cycle time and specifications.

← Previous
ADB Scenario Simulator
Next →
Vibration Micro-Drop Test

Start a project

Let's scope your E522.88 Programmers.

Send us a sample, a drawing or just a description. An engineer, not a salesperson, will reply within one working day.