Burn-in trolley
From manual boxes to monitored, mobile burn-in.
- 12 slots, each with live current per function
- Test time and current thresholds set from the GUI
- Clamp interlock and punch marking on pass
04 · EOL & Burn-in
Every lamp function switched over its real bus and checked against limits.
Monitored 12-slot burn-in trolleys and end-of-line function testers for CAN, CAN-FD and LIN lamps, with current thresholds per function and optional lumen measurement.
slots per burn-in trolley
lamp functions monitored (HB
optional light measurement
Burn-in often happens in simple boxes with indicator lamps and an operator watching. Our 12-slot trolley measures the current of every function in every slot for the full burn-in time and records it, so a lamp that drifts at hour two is caught and documented.
Add AMS light sensors for high beam, low beam and DRL to check light output on top of current. Each function and each lamp model has its own lumen limits, and readings are stored with the lamp result.
Interactive
How it works
The lamp is identified and its test recipe loaded.
Current with the lamp powered but idle.
The lamp is woken on CAN, CAN-FD or LIN.
Each function is switched on and its current checked against its window.
Software and hardware versions and stored fault codes are read.
The lamp returns to sleep and its sleep current is measured.
The result is shown and logged to the lamp serial.
Configurations
From manual boxes to monitored, mobile burn-in.
The final gate before packing.
Specifications
Final configuration is designed to your parts, cycle time and specifications.
Start a project
Send us a sample, a drawing or just a description. An engineer, not a salesperson, will reply within one working day.