Skip to content

04 · EOL & Burn-in

EOL Burn & Function Test

Every lamp function switched over its real bus and checked against limits.

Monitored 12-slot burn-in trolleys and end-of-line function testers for CAN, CAN-FD and LIN lamps, with current thresholds per function and optional lumen measurement.

CANCAN-FDLINUDSTraceability
Fuelbox 12-slot burn-in trolley with headlamps, per-slot indicators, HMI and status tower
12

slots per burn-in trolley

7

lamp functions monitored (HB

0–1000 lm

optional light measurement

From manual boxes to monitored trolleys

Burn-in often happens in simple boxes with indicator lamps and an operator watching. Our 12-slot trolley measures the current of every function in every slot for the full burn-in time and records it, so a lamp that drifts at hour two is caught and documented.

Optional light measurement

Add AMS light sensors for high beam, low beam and DRL to check light output on top of current. Each function and each lamp model has its own lumen limits, and readings are stored with the lamp result.

Interactive

A typical EOL test sequence

  1. 01Scan serial
  2. 02Quiescent current
  3. 03Bus wake-up
  4. 04Each function ON
  5. 05Read SW/HW & DTCs
  6. 06Sleep current
  7. 07Result + log
Lamp — · CAN-FD
HB
—
LB
—
DRL
—
POS
—
TURN
—
CORN
—
FOG
—
Quiescent —Sleep —DTC —Result —

How it works

  1. 01

    Scan serial

    The lamp is identified and its test recipe loaded.

  2. 02

    Quiescent current

    Current with the lamp powered but idle.

  3. 03

    Bus wake-up

    The lamp is woken on CAN, CAN-FD or LIN.

  4. 04

    Each function ON

    Each function is switched on and its current checked against its window.

  5. 05

    Versions & DTCs

    Software and hardware versions and stored fault codes are read.

  6. 06

    Sleep current

    The lamp returns to sleep and its sleep current is measured.

  7. 07

    Result + log

    The result is shown and logged to the lamp serial.

Configurations

Burn-in trolley

From manual boxes to monitored, mobile burn-in.

  • 12 slots, each with live current per function
  • Test time and current thresholds set from the GUI
  • Clamp interlock and punch marking on pass

EOL function tester

The final gate before packing.

  • CAN, CAN-FD and LIN lamps
  • Scripted sequences per lamp model
  • Optional AMS light sensors for HB, LB and DRL in a light-tight chamber

Specifications

Buses
CAN, CAN-FD, LIN
Functions
HB, LB, DRL, position, turn, cornering, fog
Measurements
Function current, quiescent and sleep current
Diagnostics
UDS — SW/HW version
Optional
AMS light sensor per function, 0–1000 lm, 1 lm accuracy

Final configuration is designed to your parts, cycle time and specifications.

← Previous
LIN RGB Test & Calibration
Next →
Production Traceability

Start a project

Let's scope your EOL Burn & Function Test.

Send us a sample, a drawing or just a description. An engineer, not a salesperson, will reply within one working day.